- The VERTICAL CENTER NEXUS 510C-II 5X 5-axis Vertical Machining Center combines advanced technology, productivity and value for a wide variety of applications. Built on the proven reliability of the VCN-510C platform, with a trunnion style NC rotary table and the MATRIX II CNC full 5 axis contouring in a comprehensive package is easily achieved.
- Used Mazak CNC Machines Lathes, Mills, HMCs, Machining. Used CNC Machinery Dealer Mazak. Used Mazak CNC Machine Dealer Lathes and Mills.
Mazak System / Drive Alarms Error Codes List for MAZATROL MATRIX etc.
For other Mazak alarm lists visit following pages.
Jan 27, 2005 Well, we have had a 410a for a few years. And we have had a Haas for a few weeks. I would trade that nexus anyday for another Hass. Ease of use and even surface finish is better with the Hass. Plus Mazaks come with windoz 95. Might well be 3.1. Good luck with the support for that. Cant even get em to load network card drivers. CNC Mazak Vertical Nexus 510C-II & 530C-II. The CNC Mazak Vertical Nexus 510C-II and the CNC Mazak Vertical Nexus 530C-II combine advanced technology, productivity, and value for a wide variety of applications. Mazak 510 Machine Specifications.
- Mazak System/Drive error ( No. 1 – No. 99, No. 1000 – No. 1099 )
- Mazak I/O error ( No. 500 – No. 599, No. 1500 – No. 1599 )
- Mazak MAZATROL program error ( No. 600 – No. 699, No. 1600 – No. 1699 )
- Mazak MAZATROL program error ( No. 700 – No. 799, No. 1700 – No. 1799 )
- Mazak EIA/ISO program error ( No. 800 – No. 899, No. 1800 – No. 1899 )
- Mazak EIA/ISO program error ( No. 900 – No. 999, No. 1900 – No. 1999 )
- Mazak Interference error ( No. 2100 – No. 2199 )
Contents
- System / Drive Error
System / Drive Error
1 EMERGENCY STOP
Clash of clans private server mac download. Cause —--
Action —--
Action —--
2 EMERGENCY STOP
Cause
Trouble has occurred in the hardware.
Action
Turn power off and then back on. If this does not clear the alarm status, require Mazak Technical Center or Technology Center to replace the defective hardware or cables.
Trouble has occurred in the hardware.
Action
Turn power off and then back on. If this does not clear the alarm status, require Mazak Technical Center or Technology Center to replace the defective hardware or cables.
3 EMERGENCY STOP
Cause
The emergency stop button on the operating panel has been pressed.
Action
Release the pressed state of the emergency stop button and reset the NC unit to its initial state.
The emergency stop button on the operating panel has been pressed.
Action
Release the pressed state of the emergency stop button and reset the NC unit to its initial state.
5 SYSTEM SOFTWARE ERROR
Cause
The contents of the system software and/or custom software have been destroyed.
Action
Contact Mazak Technical Center or Technology Center.
The contents of the system software and/or custom software have been destroyed.
Action
Contact Mazak Technical Center or Technology Center.
6 REMOTE I/O ERROR
Cause —--
Action
Contact Mazak Technical Center or Technology Center.
Action
Contact Mazak Technical Center or Technology Center.
7 SRAM MALFUNCTION
Cause
The S-RAM mounted on the CPU card has become abnormal.
Action
Contact Mazak Technical Center or Technology Center.
The S-RAM mounted on the CPU card has become abnormal.
Action
Contact Mazak Technical Center or Technology Center.
Mazak Nexus 410a Manual 2
8 RAM MALFUNCTION
Cause
The RAM mounted on the CPU card has become abnormal.
Action
Contact Mazak Technical Center or Technology Center.
The RAM mounted on the CPU card has become abnormal.
Action
Contact Mazak Technical Center or Technology Center.
9 ABSOLUTE POSITION MALFUNCTION
Cause
The absolute position detection system has lost absolute position data.
Action
Require Mazak Technical Center or Technology Center to re-set the absolute position data.
The absolute position detection system has lost absolute position data.
Action
Require Mazak Technical Center or Technology Center to re-set the absolute position data.
10 DETECTOR MALFUNCTION
Cause
The absolute position detection system has detected its detector error(s).
Action
Require Mazak Technical Center or Technology Center to replace the encoder or bettery.
The absolute position detection system has detected its detector error(s).
Action
Require Mazak Technical Center or Technology Center to replace the encoder or bettery.
11 POSITION REFERENCE MALFUNCTION
Cause
The absolute position detection system has detected an error(s) by cross-checking the absolute position of its detector and the internal coordinate data of the NC unit.
Action
Require Mazak Technical Center or Technology Center to re-set the absolute position data.
The absolute position detection system has detected an error(s) by cross-checking the absolute position of its detector and the internal coordinate data of the NC unit.
Action
Require Mazak Technical Center or Technology Center to re-set the absolute position data.
12 ABSOLUTE POSITION WARNING
Cause
The absolute position detection system has detected abnormal data.
Action
The battery is running down. Require Mazak Technical Center or Technology Center to replace the battery.
The absolute position detection system has detected abnormal data.
Action
The battery is running down. Require Mazak Technical Center or Technology Center to replace the battery.
13 PRE-PROCESSOR MALFUNCTION
Cause
The software is not correctly working.
Action
Require Mazak Technical Center or Technology Center to re-write the NC system data.
The software is not correctly working.
Action
Require Mazak Technical Center or Technology Center to re-write the NC system data.
21 SYSTEM ERROR
Cause
Trouble has occurred during communication with the amplifiers or during communication data processing.
Action
Contact Mazak Technical Center or Technology Center with the information of the numbers (Alarm No. and Sub No.) displayed in parentheses.
Trouble has occurred during communication with the amplifiers or during communication data processing.
Action
Contact Mazak Technical Center or Technology Center with the information of the numbers (Alarm No. and Sub No.) displayed in parentheses.
22 AMPLIFIER NOT EQUIPPED
Cause
Amplifier power is not yet turned on. Or no signals are transferred yet. There is a discrepancy between the channel and rotary switch Nos. of the amplifier and the parameters concerned.
Action
Check for an incorrectly connected cable, an incorrectly attached connector, an inadequate input supply voltage to the amplifier, an incorrect axis-number switch setting, etc. Check the settings of parameters N17, N18, SA43, and SA44 for incorrectness.
Amplifier power is not yet turned on. Or no signals are transferred yet. There is a discrepancy between the channel and rotary switch Nos. of the amplifier and the parameters concerned.
Action
Check for an incorrectly connected cable, an incorrectly attached connector, an inadequate input supply voltage to the amplifier, an incorrect axis-number switch setting, etc. Check the settings of parameters N17, N18, SA43, and SA44 for incorrectness.
26 SPINDLE SAFE OPER. SYSTEM ALARM
Cause
Trouble has occurred for the spindle in the mode of safety-speed operation. See the description of No. 25 above for the details of probable causes.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
Trouble has occurred for the spindle in the mode of safety-speed operation. See the description of No. 25 above for the details of probable causes.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
31 SERVO MALFUNCTION 1
Cause
The servo (power-off level) is abnormal.
Action
Require Mazak Technical Center or Technology Center to replace the servo amplifier.
The servo (power-off level) is abnormal.
Action
Require Mazak Technical Center or Technology Center to replace the servo amplifier.
32 SERVO PARAMETER MALFUNCTION
Cause
The parameters that have been transferred from the NC unit to the servo amplifier during NC power-on are not correct. Action Require Mazak Technical Center or Technology Center to re-set the servo parameters.
The parameters that have been transferred from the NC unit to the servo amplifier during NC power-on are not correct. Action Require Mazak Technical Center or Technology Center to re-set the servo parameters.
33 SERVO MALFUNCTION 2
Cause
The servo (NC reset level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
The servo (NC reset level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
34 SERVO MALFUNCTION 3
Cause
The servo (amplifier power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center.
The servo (amplifier power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center.
35 OVERLOAD
Cause
An extraordinary overload has been detected.
Action
Check if any collision has occurred on the machine and perform the corresponding recovery, or check and reduce the cutting conditions. If other measures other than the above should be taken, contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
An extraordinary overload has been detected.
Action
Check if any collision has occurred on the machine and perform the corresponding recovery, or check and reduce the cutting conditions. If other measures other than the above should be taken, contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
41 SPINDLE MALFUNCTION 1
Cause
The spindle (power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
The spindle (power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
42 SPINDLE PARAMETER MALFUNCTION
Cause
The parameters that have been transferred from the NC unit to the spindle amplifier during NC power-on are not correct.
Action
Require Mazak Technical Center or Technology Center to re-set the spindle parameters.
The parameters that have been transferred from the NC unit to the spindle amplifier during NC power-on are not correct.
Action
Require Mazak Technical Center or Technology Center to re-set the spindle parameters.
43 SPINDLE MALFUNCTION 2
Cause
The spindle (NC reset level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
The spindle (NC reset level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
44 SPINDLE MALFUNCTION 3
Cause
The spindle (amplifier power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
The spindle (amplifier power-off level) is abnormal.
Action
Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
51 E2ROM MALFUNCTION
Cause
Trouble has occurred during communication with MR-JT-C2. Parameters cannot be correctly written into the E2ROM.
Action
Require Mazak Technical Center or Technology Center to replace the MR-JT-C2 amplifier.
Trouble has occurred during communication with MR-JT-C2. Parameters cannot be correctly written into the E2ROM.
Action
Require Mazak Technical Center or Technology Center to replace the MR-JT-C2 amplifier.
52 BATTERY ALARM
Cause
The battery provided to retain parameters, machining programs and other types of data within the NC unit has reached the minimum voltage level permissible or has run down.
Action
It is required that the machining data is rechecked for possible loss or that the battery is recharged or replaced. For battery recharging or replacement, refer to the relevant description given in the Maintenance Manual.
The battery provided to retain parameters, machining programs and other types of data within the NC unit has reached the minimum voltage level permissible or has run down.
Action
It is required that the machining data is rechecked for possible loss or that the battery is recharged or replaced. For battery recharging or replacement, refer to the relevant description given in the Maintenance Manual.
53 NC TEMPERATURE WARNING
Cause
The temperature of the control unit or operation board has increased above the required level. (Note 1: Location of the temperature alarm, Note 2: Type of temperature alarm, Note 3: On-alarm temperature value)
Action
Reduce the temperature by turning off the NC power or by mounting a cooling unit.
The temperature of the control unit or operation board has increased above the required level. (Note 1: Location of the temperature alarm, Note 2: Type of temperature alarm, Note 3: On-alarm temperature value)
Action
Reduce the temperature by turning off the NC power or by mounting a cooling unit.
54 DIO5V MALFUNCTION
Cause
--
Action
Contact Mazak Technical Center or Technology Center.
--
Action
Contact Mazak Technical Center or Technology Center.
56 SYSTEM SOFTWARE CHECKING
Cause
The ROMs mounted in the system ROM card are currently being checked for abnormalities.
Action
Wait for a while. Contact Mazak Technical Center or Technology Center if the alarm is not cleared. Inpixio photo clip mac torrent.
The ROMs mounted in the system ROM card are currently being checked for abnormalities.
Action
Wait for a while. Contact Mazak Technical Center or Technology Center if the alarm is not cleared. Inpixio photo clip mac torrent.
57 NO PLC
Cause
The user PLC is not stored in the NC unit.
Action
Contact Mazak Technical Center or Technology Center.
The user PLC is not stored in the NC unit.
Action
Contact Mazak Technical Center or Technology Center.
58 CORRUPT PLC
Cause
Trouble has occurred with the PLC.
Action
Contact Mazak Technical Center or Technology Center with the information of the second item (Status) displayed in parentheses.
Trouble has occurred with the PLC.
Action
Contact Mazak Technical Center or Technology Center with the information of the second item (Status) displayed in parentheses.
Intel tv wizard windows 7 free. Windows Vista/7/8: Click Uninstall a Program. Windows XP: Click Add or Remove Programs. When you find the program Intel(R) TV Wizard, click it, and then do one of the following: Windows Vista/7/8: Click Uninstall. Windows XP: Click the Remove or Change/Remove tab (to.
59 PLC STOPPED
Cause
The PLC has ceased running.
Action
Contact Mazak Technical Center or Technology Center.
The PLC has ceased running.
Action
Contact Mazak Technical Center or Technology Center.
66 PARAMETER MALFUNCTION
Cause
—--
Action
Contact Mazak Technical Center or Technology Center.
—--
Action
Contact Mazak Technical Center or Technology Center.
67 ILLEGAL HI-SPEED SYNCTAP AXIS
Cause
A servo with a system not applicable to high-speed synchronous tapping is connected in spite of the high-speed synchronous tapping option being valid.
Action
Contact Mazak Technical Center or Technology Center.
A servo with a system not applicable to high-speed synchronous tapping is connected in spite of the high-speed synchronous tapping option being valid.
Action
Contact Mazak Technical Center or Technology Center.
68 ILLEGAL HI-SPEED SYNCTAP SPDL
Mazak Nexus 5000
Cause
A servo with a system not applicable to high-speed synchronous tapping is connected in spite of the high-speed synchronous tapping option being valid.
Action
Contact Mazak Technical Center or Technology Center.
A servo with a system not applicable to high-speed synchronous tapping is connected in spite of the high-speed synchronous tapping option being valid.
Action
Contact Mazak Technical Center or Technology Center.
71 ILLEGAL SERVO PARAMETER
Cause
The parameters that have been transferred from the NC system to the servo amplifier during NC power-on are not correct.
Action
Contact Mazak Technical Center or Technology Center.
The parameters that have been transferred from the NC system to the servo amplifier during NC power-on are not correct.
Action
Contact Mazak Technical Center or Technology Center.
72 SERVO WARNING
Cause
The servomotor is loaded abnormally.
Action
Turn off the NC and the machine, remove the cause of the abnormal load, and then turn on the machine and the NC. Contact Mazak Technical Center or Technology Center if the alarm is not cleared.
The servomotor is loaded abnormally.
Action
Turn off the NC and the machine, remove the cause of the abnormal load, and then turn on the machine and the NC. Contact Mazak Technical Center or Technology Center if the alarm is not cleared.
81 ILLEGAL SPINDLE PARAMETER
Mazak Nexus 410a Manual Diagram
Cause
The parameters that have been transferred from the NC system to the spindle amplifier during NC power-on are not correct.
Action
Contact Mazak Technical Center or Technology Center.
The parameters that have been transferred from the NC system to the spindle amplifier during NC power-on are not correct.
Action
Contact Mazak Technical Center or Technology Center.
82 SPINDLE WARNING
Mazak Nexus 410a Manual 1
Cause
The spindle amplifier is loaded abnormally.
Action
Turn off the NC and the machine, remove the cause of the abnormal load, and then turn on the machine and the NC.
The spindle amplifier is loaded abnormally.
Action
Turn off the NC and the machine, remove the cause of the abnormal load, and then turn on the machine and the NC.